Overview
Prevent overloaded circuits and breaker trips by automatically prioritizing power between two appliances on a single 20A branch circuit.
The AIMS Power Energy Management Switch (EMS) is a practical power management solution designed to protect circuits that supply multiple appliances from a single 20A source. When two loads attempt to run simultaneously, such as mid to large size appliances, the EMS intelligently manages power distribution to prevent nuisance breaker trips.
The system monitors total current and allows both loads to operate normally until consumption approaches the circuit limit. When the load exceeds approximately 18A, the EMS automatically disconnects the secondary appliance while maintaining uninterrupted power to the primary load. Once current demand drops below the preset threshold, the secondary load is restored automatically.
This makes the EMS ideal for installations using inverter power, shore power, or generator input, where limited circuit capacity must safely support multiple loads.
• Users: Prevents breaker trips when two appliances start at the same time while keeping the primary appliance running.
• Installers: Simple wiring configuration with one AC input and two output circuits, with Circuit A as the priority branch and Circuit B as the secondary load.
Why AIMS Power?
AIMS Power designs power-management solutions that focus on reliability, protection, and practical installation. The Energy Management Switch is engineered to intelligently regulate load demand on a limited 20A circuit while maintaining uninterrupted operation for priority equipment. With automatic load control, installer-friendly wiring, and dependable electronic monitoring, it delivers durable long-term performance in inverter, generator, or shore-power systems.
Features
Features:
Automatic Circuit Protection: Continuously monitors total load current and automatically disconnects the secondary load when demand exceeds approximately 18A to prevent breaker trips. Allows two appliances to operate from a single branch circuit that would normally require separate breakers.
Compressor Friendly Long Delay: Long Delay mode uses an approximately three-minute OFF delay before restoring the secondary circuit once current has fallen below approximately 5A.
Automatic Load Restoration: Once system demand drops below approximately 5A, the EMS automatically restores power to the secondary circuit without user intervention.
Simple DIP Switch Configuration: Installers can select Short Delay with DIP switch position “0” or Long Delay with position “1” to match the connected appliance application.
Flexible Power Source Compatibility: Works with inverter, shore power, or generator inputs, making it suitable for multiple power system configurations.
Installer Adjustable Delay Control: Built-in dip switch delay control allows installers to manage switching behavior during load transitions.
Rugged Reliability: Heavy duty electrical management circuitry and robust construction support long term operation in demanding power environments.
Description
The Energy Management Switch (EMS) provides a cost effective solution for power management and added protection for applications using inputs from an inverter, shore OR generator that have a single 20A branch circuit. The EMS is designed to be used anywhere where two loads share the power from a single 20A branch circuit that normally require their own breaker. Most common applications are mid to large appliances that may kick on at the same time, overloading the circuit. The EMS applies power to both loads until the total loaded current exceeds approximately 18 Amps AC. It then cuts the power to the secondary load to prevent the 20A circuit breaker from tripping, while maintaining power to the primary load. The secondary load will be restored automatically when the total loaded current drops below a preset level (~5A).
The EMS has one input and two outputs. The primary (priority) branch is Circuit A. The secondary load (which may be shut off) is to be wired to Circuit B.
- AC input voltage and frequency: 120 VAC 50/60 Hz
- AC input current: 18 A (max)
- AC output voltage and frequency: 120 VAC 50/60 Hz
- AC output current: 18 A (max)
- Dip switch to control delay
- Weight: 2 lbs
- Dimensions: 7.25L” x 6.5D” x 2.37H”
- Mounting holes center to center: 3.5″
Recommend wire size: 12 AWG minimum and 8 AWG maximum
Protected by a 5‑year manufacturer defect warranty and lifetime tech support.
Download manual here